icono contacto

Autoclaves > Top line verticals TLV-FA Series

TLV-FA Series

Vertical autoclaves with fast cooling system

Designed specifically for the pharmaceutical and biotech industries, the TLV-FA Series vertical autoclaves excel in sterilizing liquid loads thanks to their fast cooling system that includes pressure support.

  • Up to 60% faster sterilization of liquids
  • Fully automatic, equipped with cutting-edge engineering and exceptional quality in every detail
  • Advanced cloud-based connectivity that complies with FDA, GMP, and GLP standards

  • WATCH VIDEO

  • Vista frontal de la autoclave TLV-FA de RAYPA%
  • %
  • Rear view of RAYPA's TLV-FA autoclave%
  • %
  • %
  • Sterilization of bioreactor in autoclave TLV-FA%
  • RAYPA autoclave handling%
  • Door opening of the RAYPA TLV-S autoclave%
  • RAYPA Advanced Technical Support%
  • %
  • RAYPA TLV-FA Autoclave%
  • RAYPA connectivity accessories%
  • Bar code reader%

Vertical laboratory autoclaves with fast cooling system

The TLV-FA Series vertical autoclaves are equipped with a fast cooling system including water coil, air compressor, internal fan and flexible probes. They are specially designed to provide advanced liquid sterilization in industrial and research environments in the pharmaceutical, chemical and biotechnology industries sterilizing aqueous solutions, liquid agar, lysogenic broth or pre-filled syringes. They can also process solid loads.

Top line vertical autoclaves enable fully digital operation. All models are equipped with the most advanced connectivity on the market and comply with the latest advances in electronic records and data control to be able to work under FDA, GMP and GLP environments.

Sistema de enfriado rápido compuesto por ventilador radial, serpentín de agua y compresor de aire

State-of-the-art technology for advanced liquid sterilization

Thanks to its fast cooling system consisting of a radial fan, water coil and air compressor, you will be able to sterilize liquid loads more quickly. Install up to 2 flexible probes and conduct F₀-controlled sterilizations.

Modern design and fully automatic

State-of-the-art technology. Push-button-controlled mechanically assisted door. Instant steam production by the built-in steam generator. Air inlet and outlet fitted with a bacteriological filter. Equipped with a vacuum pump and an air compressor. High-performance fast cooling system composed of water cooling coils, internal radial fan and pressure support. Automatic filling from the water network. Water-cooled direct discharge.

detail TLV FA
Cloud-based connectivity and advanced technical support

Cloud-based connectivity and advanced technical support

Advanced technical support: Book and request technical assistance directly from the controller, use TeamViewer® for screen sharing, and authorize a remote diagnosis of the equipment's status. Additionally, enjoy centralized management for several autoclaves with tailored reports, handle notifications across multiple devices, and ensure automatic traceability for audits, all protected with SSL encryption. The cloud-based management software is adaptable for integration on a private server through Docker, Active Directory, or LIMS.

Operation

Temperature

Pressure

TLVFA

A
B
C
D
TLV FA A
TLV FA B
TLV FA C
TLV FA D
A. Prevacuum phase
In this phase the cold air in the chamber is mechanically purged to the outside by means of a vacuum pulse, reducing the presence of non-condensable gases and facilitating the penetration of steam throughout the load.
B. Heating phase
After completing the first vacuum pulse, the steam generator is activated and will inject saturated steam into the sterilization chamber until the sterilization temperature is reached.
C. Sterilization phase
Upon reaching the sterilization temperature in the medium, the sterilization phase begins and the temperature is accurately sustained for the predefined duration.
D. Fast cooling phase
Finally, a fast cooling phase begins, featuring pressure support along with the activation of the water cooling coils and internal radial fan to quickly cool the load. Optionally, the agar mode can be configured to maintain a constant temperature.

Operation

In this phase the cold air in the chamber is mechanically purged to the outside by means of a vacuum pulse, reducing the presence of non-condensable gases and facilitating the penetration of steam throughout the load.

Temperature

Pressure

TLV-FA_mobile_cycle_A

After completing the first vacuum pulse, the steam generator is activated and will inject saturated steam into the sterilization chamber until the sterilization temperature is reached.

Temperature

Pressure

TLV-FA_mobile_cycle_B

Upon reaching the sterilization temperature in the medium, the sterilization phase begins and the temperature is accurately sustained for the predefined duration.

Temperature

Pressure

TLV-FA_mobile_cycle_C

Finally, a fast cooling phase begins, featuring pressure support along with the activation of the water cooling coils and internal radial fan to quickly cool the load. Optionally, the agar mode can be configured to maintain a constant temperature.

Temperature

Pressure

TLV FA mobile ciclo D

Applications

Technical data

References
Total/usable volume of the chamber (L)
Usable dimensions of the chamber (Ø x H mm)
External dimensions (L x D x H mm)
Loading height (mm)
Net weight (Kg)
Power (W)
Voltage* (V)
Frequency (Hz)
*Other voltages and electrical configurations available on request.

Accessories

You may also be interested in

Subscribe to our newsletter