Autoclaves > Classic line AE-MP Series
Standard media preparators
Automatic, safe, and efficient solution for preparing culture media.
- Automatic preparation and fast dispensing
- Cost savings, reduced preparation time, and decreased workload
- Flexibility and scalability: 6 models and 4 modes of dispensing
Culture media preparators
The media preparators from the AE-MP Series optimize the workflow of microbiology and plant tissue culture laboratories by saving on costs, preparation time, and workload.
A single device encompasses the preparation, sterilization, fast cooling, and dispensation of high-quality culture media with excellent batch-to-batch reproducibility. Its design prevents contamination, gelation, solubility, or homogeneity issues, as well as burns.
The media preparators from the AE-MP Series are designed to reduce the total preparation time and provide large volumes of culture media. Choose the configuration that best suits your laboratory from among the 6 media preparator sizes and the 4 available dispensing modes. Additionally, the heating capacity of each model can be upgraded to drastically reduce the duration of the heating phase.
Streamline your preparation time, speed up dispensation and reduce workload
Enjoy much faster production times compared to the traditional autoclave method. Preparation volumes range from 2L to 90L, with dispensing speeds ranging from 7 mL/s to 100 mL/s. Select the dispensation temperature that best meets your requirements.
Hassle-free cleaning with multiple automated functions
Dispensing lines can be cleaned and disinfected before, during, and after the dispensation phase with steam pulses that reach the entire length of the line to prevent contamination. You can pause the dispensation phase to avoid gelling issues. The inner vessel features ergonomic handles and can be easily removed.
Sterilize professionally with excellent reproducibility
The use of the flexible probe and F₀ regulation allows sterilizations to be performed with maximum precision. Ability to configure programs with ramps for preparing special recipes. Minimizes concerns regarding contamination, precipitation, homogeneity, or overcooking. Record and analyze the processing of each batch.
Operation
Temperature
Pressure
Operation
The powerful heating elements of the sterilization chamber heat up water to produce saturated steam and warm the culture media located inside the inner vessel. Simultaneously, the magnetic stirrer of adjustable stirring speed, ensures the correct dissolution of the solute in the solvent.
Temperature
Pressure
Upon reaching the sterilization temperature in the medium, the sterilization phase begins and the temperature is accurately sustained for the predefined duration.
Temperature
Pressure
Finally, a fast cooling phase begins with pressure support, activating the water coils that surround the sterilization chamber to quickly cool the load until it reaches the dispensation temperature, which will be maintained indefinitely until all the prepared culture medium is dispensed. Antibiotics, pH correctors or thermolabile ingredients can be dispensed at any time using the external dispensing ports.
Temperature
Pressure
Applications
Preparation of agar
The fast cooling system saves a lot of time. Additionally, you can start dispensing the sterilized medium whenever you want since the temperature is maintained at the chosen temperature indefinitely. Likewise, the dispensing process can be interrupted and resumed later thanks to the pressure support system, preventing the agar in the dispensing lines from solidifying.
Plant tissue culture
Thanks to dispensation through pressure support, you can dispense large volumes at high speed. Additionally, larger models can be overpowered, which, along with fast cooling, allows for a drastic reduction in the duration of each cycle. pH correctors can be dispensed at any time using the external dispensing ports.
Preparation of buffer solution
Thanks to dispensation through pressure support, you can dispense large volumes at high speed. Additionally, larger models can be overpowered, which, along with fast cooling, allows for a drastic reduction in the duration of each cycle. pH correctors can be dispensed at any time using the external dispensing ports.
Preparation of lysogeny broth
Thanks to dispensation through pressure support, you can dispense large volumes at high speed. Additionally, larger models can be overpowered, which, along with fast cooling, allows for a drastic reduction in the duration of each cycle.
Technical data
References |
---|
Maximum capacity for preparing culture media (L) |
Minimum capacity for preparing culture media* (min. by F0 - min. by time) (L) |
External dimensions (L x D x H mm) |
Inner vessel dimensions (Ø x H mm) |
Net weight (Kg) |
Power** (kW) |
Voltage** (V) |
Frequency (Hz) |
AE-20-MP-10L |
8 |
2 - 5 |
615 x 815 x 735 |
210 x 236 |
125 |
3 |
230 |
50/60 |
AE-20-MP |
18 |
2 - 10 |
615 x 815 x 735 |
330 x 236 |
128 |
3 |
230 |
50/60 |
AE-40-MP |
36 |
5 - 20 |
615 x 815 x 1100 |
330 x 461 |
135 |
6 or 12 |
400 |
50/60 |
AE-60-MP |
54 |
10 - 30 |
615 x 815 x 1320 |
330 x 696 |
155 |
9 or 15 |
400 |
50/60 |
AE-80-MP |
72 |
10 - 50 |
755 x 935 x 1285 |
420 x 594 |
244 |
15, 20 or 30 |
400 |
50/60 |
AE-100-MP |
90 |
20 - 70 |
755 x 935 x 1385 |
420 x 734 |
265 |
15, 20 or 30 |
400 |
50/60 |
*The minimum volume capacity is much lower if F0-controlled sterilization is performed instead of control by time at 121ºC. Contact our technical service to receive more information. | **Other voltages and electrical configurations available on request. Special models with increased power may operate with other voltages. |
Accessories
Automatic system for dispensing culture media
Fast and automated system for dispensing culture media into Petri dishes.
External dosing station
Automates and speeds up the dispensing phase of repetitive operations.
Integrated thermal printer
It prints the program number, cycle and the evolution of parameters in the course of the cycle.
External probe for qualification
Set of reader and two specific temperature probes for performing the calibration or qualification of media preparators.
External probe adapter
Adapter for external validation probe.
Additional peristaltic pump
Second peristaltic pump to double the dispensing flow rate.
Dispensing lines
Silicone dosing tubes to increase dispensing speed.
Splitting of dispensing lines
Custom modification to divide the dispensing lines, enabling the supply of two distinct workstations from a single media preparator.
Compressed air system
Pressure support system to avoid loss of liquid by evaporation.
Automatic water filling
Water pump for automating the supply of the sterilization chamber with purified water.
Eco-efficient water purifier
Eco-efficient direct-flow water purifier without water storage, capable of filtering 1.3L/min with an LED display.
Desktop dot matrix printer
Prints program number, cycle number, temperature, time, date and time of each sterilization, and error messages.
SWMP Software
Communication software between the equipment and the PC for display and recording in real time or display after each cycle.
Temperature recorder
Datalogger in disk format to monitor the temperature inside a load
Table for media preparators
Stainless steel table for placing benchtop media preparators or the CAR-MP dispensing system at an optimal height.
Transport trolley
Auxiliary trolley to assist in loading and unloading the autoclave.
IQ-OQ Documentation
Delivery of IQ/OQ documentation and protocol to perform a third-party qualification of the media preparator.
IQ-OQ-PQ qualification
IQ/OQ/PQ autoclave qualification service performed by RAYPA.
On-site commissioning & training
On-site commissioning, which includes verification of the correct operation and installation of the equipment and a training session for users on the use and maintenance of the equipment.
Remote commissioning & training
Guided remote start-up including a training session for users on the operation and maintenance of the equipment.
Maintenance contract
Regular inspection plan that includes technical inspection, probe calibration and compliance with the preventive maintenance plan, as well as tariff discounts, all performed by our expert technicians.
Set of spare parts and essential components
Set of spare parts, critical components and original consumables selected to comply with the maintenance plan of each model with the objective of maximizing the useful life of the equipment and minimizing downtime in case of failure.
Warranty extension
Extended warranty up to a total of 3 years
You may also be interested in
Subscribe to our newsletter
"*" indicates required fields