Autoclaves > Classic line verticals AES Series
Vertical autoclaves without drying
The AES Series vertical laboratory autoclaves without drying are designed to sterilize a wide variety of laboratory materials in an economical and straightforward manner.
- Cost-effective with robust performance
- Easy to use, simple installation and minimal maintenance
- Excellent construction materials
Vertical laboratory autoclaves without drying
The AES Series vertical autoclaves meet the fundamental sterilization needs in industrial, educational and research facility laboratories to increase productivity and simplify sterilization operations.
They are designed for sterilizing a wide range of solid and liquid loads, including glass, plastics, metal utensils, laboratory waste bags, liquids, culture media and other laboratory items.
Suitable for the general laboratory, they are optimized for easy operation, feature multiple safety characteristics to protect users in their daily routine, and are very simple to install as they are plug and play equipment.
Economical, resilient and limited resource consumption
Built using high-quality construction materials, they feature a sterilization chamber made of exceptionally resistant AISI-316L stainless steel, with the external building also made of stainless steel. The components are sourced from top-tier manufacturers. Limited consumption of water, energy and operator time.
Customize with a range of accessories
Choose the baskets and crane that best fit your needs. Install a flexible probe for more accurate and safe sterilization of liquids. Record and analyze your processes with dedicated software or an embedded printer. You can also enhance the heating capacity of your unit to save time.
Easy installation and simple maintenance, no specific connections required
No specific connections are required for installation; all models are plug and play, only requiring an electrical connection.
Operation
Temperature
Pressure
Operation
The heating elements heat up water to produce saturated steam, which expels the cold air outward until the sterilization temperature is achieved in the chamber.
Temperature
Pressure
Upon reaching the sterilization temperature in the medium, the sterilization phase begins and the temperature is accurately sustained for the predefined duration.
Temperature
Pressure
At the end of the sterilization phase, a natural cooling phase begins. In solids programs, discharge can be manually forced through a push-button to reduce the duration of the cooling phase. In programs with agar mode activated, the preset temperature is maintained indefinitely.
Temperature
Pressure
Applications
LIQUIDS AND CULTURE MEDIA
The agar mode maintains the temperature and prevents the culture media from gelling. Installing a flexible probe allows for more precise sterilization of liquid loads.
PLASTICS AND METAL OBJECTS
Activating the rapid steam release button allows for faster cooling in solid loads.
GLASSWARE
Activating the rapid steam release button allows for faster cooling in solid loads.
LABORATORY WASTE BAGS
For this application, the sterilization time should be extended and chemical and/or biological tests should be used to validate the correct sterilization of the load.
Technical data
References |
---|
Total/usable volume of the chamber (L) |
Usable dimensions of the chamber (Ø x H mm) |
External dimensions (L x D x H mm) |
Loading height (mm) |
Net weight (Kg) |
Power (W) |
Voltage* (V) |
Frequency (Hz) |
AES-28 |
33/31 |
300 x 440 |
505 x 580 x 1110 |
795 |
61 |
2000 or 3200 |
230 |
50/60 |
AES-50 |
55/50 |
300 x 710 |
505 x 580 x 1290 |
975 |
65 |
3200 or 5000 |
230 |
50/60 |
AES-75 |
79/75 |
400 x 600 |
610 x 700 x 1185 |
870 |
98 |
3200 or 6000 |
230 |
50/60 |
AES-110 |
115/110 |
400 x 850 |
610 x 700 x 1435 |
1120 |
122 |
4500, 6000 or 9000 |
400 |
50/60 |
AES-150 |
175/153 |
500 x 780 |
750 x 820 x 1400 |
1085 |
198 |
6000 or 9000 |
400 |
50/60 |
*Other voltages and electrical configurations available on request. Special models with increased power may operate with other voltages. |
Accessories
Flexible probe
Flexible temperature probe to improve the sterilization of liquid loads.
Integrated thermal printer
Prints program number, cycle number, temperature, date and hour of the run and error messages.
Integrated basket lifting crane
Mobile crane integrated into the side of the autoclave, designed to assist in the loading and unloading of heavy items.
Mobile basket lifting crane
Crane with integrated battery, mobile and independent, designed to assist in the loading and unloading of heavy items.
Wire baskets
Baskets suitable for the sterilization of all types of clean loads.
Wire basket tray
Tray for use in conjunction with wire baskets to collect liquids
Unperforated baskets
Baskets suitable for sterilization of dirty loads and those at risk of spillage.
Schimmelbusch Drum
Container suitable for sterilization of instruments and biohazardous loads.
Height adjustable tray support
For sterilization of instruments, small bags and other small objects that must be placed straight up.
Cylinders with basket
Suitable for sterilization of Petri dishes with a diameter of 80 or 120mm.
Standard cylinders
Suitable for sterilizing pipette tips and other small consumables.
External dot matrix printer
Prints program number, cycle number, temperature, date and hour of the run and error messages.
SW7000 Software
Communication software between the equipment and the PC for display and recording of each cycle.
Premium casters
Higher quality casters with brakes.
Transport trolley
Auxiliary trolley to aid in the loading and unloading of equipment and containers.
Condensate bottle
12L bottle with tap for collecting condensates during the purging phase and also for collecting water during the cleaning of the sterilization chamber.
Cable gland
Cable gland allowing access for up to 8 probes for calibration and validation operations.
External temperature probe adapter
External adapter for continuous validation processes that allows obtaining a temperature reading independent of the equipment's microprocessor.
Temperature recorder
Disk-shaped datalogger for monitoring the temperature inside a load.
Sterilization control tape
Class 1 indicator for steam sterilization.
IQ-OQ Documentation
Delivery of documentation and IQ/OQ protocol for third party autoclave qualification.
IQ-OQ-PQ Qualification
IQ/OQ/PQ autoclave qualification service performed by RAYPA.
On-site commissioning & training
On-site guided start-up that includes the verification of the correct operation and installation of the equipment, complemented by a training session on its operation and maintenance for users.
Remote commissioning & training
Guided remote start-up including a training session for users on the operation and maintenance of the equipment.
Maintenance contract
A schedule of regular inspections that encompasses technical assessments, probe calibration, and adherence to the preventative maintenance plan, along with discount rates.
Set of consumables, spare parts and essential components
Set of original spare parts, consumables, and components, chosen specifically to adhere to each model's maintenance plan, intended to maximize equipment longevity and minimize downtime in the event of a malfunction.
Warranty extension
Extended warranty up to a total of 3 years.
You may also be interested in
Vertical autoclaves with drying
- AE-DRY Series
- Classic Line
Vertical laboratory autoclaves with prevacuums and drying
- AE-B Series
- Classic Line
Front-loading benchtop autoclaves without drying
- AHS-N Series
- Classic Line