Autoclaves > Classic line benchtop AVS-N-MD Series
Top-loading benchtop medical autoclaves without drying
The AVS-N-MD Series top-loading benchtop medical autoclaves without drying are small, economical and easy to use.
- Economical, cost-effective, and with robust performance
- Limited consumption of resources
- Suitable for the sterilization of a wide range of solids as well as liquids
Top-loading benchtop medical autoclaves without drying
The AVS-N-MD Series top-loading benchtop autoclaves meet the fundamental sterilization needs of clinical and healthcare facilities with the objective of simplifying sterilization operations.
They are designed for the sterilization of small solid and liquid loads, including glassware, plastics, metal instruments and sanitary waste.
Suitable for any healthcare facility, they are optimized for easy operation, include excellent safety features to protect users in their daily routine and are easy to install as they are plug and play.
Compact, economical and limited resource consumption
Sterilization chamber and external building in stainless steel. The components are sourced from top-tier manufacturers. Limited consumption of water, energy and operator time.
Easy installation and simple maintenance, no specific connections required
No specific connections are required for installation; all models are plug and play, only requiring an electrical connection. In addition, all models include a specific basket, a protective rack for the heating elements and a drainage tube.
Intuitive control panel and simplified operation
Automatic microprocessor. Integrated thermal printer and optional data export software. Valve for fast evaporation and to accelerate the cooling phase in solid sterilization cycles.
Operation
Temperature
Pressure
Operation
The heating elements heat up water to produce saturated steam, which expels the cold air outward until the sterilization temperature is achieved in the chamber.
Temperature
Pressure
Upon reaching the sterilization temperature in the medium, the sterilization phase begins and the temperature is accurately sustained for the predefined duration.
Temperature
Pressure
After completion of sterilization, a final natural cooling phase begins until a safe temperature is reached. They include a fast evaporation wheel to speed up the process in solid loads. Optionally, the agar mode can be configured to maintain a constant temperature.
Temperature
Pressure
Applications
LIQUIDS AND CULTURE MEDIA
The agar mode maintains the temperature and prevents the culture media from gelling. Installing a flexible probe allows for more precise sterilization of liquid loads.
PLASTICS
For a faster cooling phase in solids sterilization cycles, a quick unsteaming can be carried out through a manual valve and thus shorten the duration of the cooling phase.
GLASSWARE
For a faster cooling phase in solids sterilization cycles, a quick unsteaming can be carried out through a manual valve and thus shorten the duration of the cooling phase.
SANITARY WASTE
For this application, the sterilization time should be extended and chemical and/or biological tests should be used to validate the correct sterilization of the load.
METALLIC OBJECTS
For a faster cooling phase in solids sterilization cycles, a quick unsteaming can be carried out through a manual valve and thus shorten the duration of the cooling phase.
Technical data
References |
---|
Total/usable volume of the chamber (L) |
Usable dimensions of the chamber (Ø x H mm) |
External dimensions (L x D x H mm) |
Loading height (mm) |
Net weight (Kg) |
Power (W) |
Voltage* (V) |
Frequency (Hz) |
AES-12-MD |
15/13 |
250 x 280 |
490 x 475 x 630 |
435 |
38 |
1000 |
230 |
50/60 |
*Other voltages and electrical configurations available on request. |
Accessories
Wire baskets
Stainless steel rod basket suitable for sterilization of all types of loads.
Flexible probe
Add a flexible probe to improve the sterilization of liquid loads.
Integrated thermal printer
It prints the program number, cycle number, evolution of parameters in the course of the cycle, date and time of execution and error messages.
Desktop dot matrix printer
Prints program number, cycle number, temperature, time, dates and time of each sterilization and error messages.
SW7000 Software
Software to analyze and record cycles
Autoclave table
Stainless steel table with wheels with brakes. Designed to place benchtop autoclaves.
Transport trolley
Auxiliary trolley to assist in loading and unloading the autoclave.
Water distiller
Forced air water distiller with stainless steel interior, 4L capacity and 1,5L/h distillation volume.
Cable gland
Cable gland for calibration and validation procedures.
Sterilization control tape
Sterilization indicator on adhesive tape
IQ-OQ Documentation
Delivery of documentation and IQ/OQ protocol for third party autoclave qualification.
IQ-OQ-PQ Qualification
IQ/OQ/PQ autoclave qualification service performed by RAYPA.
On-site commissioning & training
On-site commissioning, which includes verification of the correct operation and installation of the equipment and a training session for users on the use and maintenance of the equipment.
Remote commissioning & training
Guided remote start-up including a training session for users on the operation and maintenance of the equipment.
Maintenance contract
Regular inspection plan that includes technical inspection, probe calibration and compliance with the preventive maintenance plan, as well as tariff discounts, all performed by our expert technicians.
Set of consumables, spare parts and essential components
Set of original spare parts, consumables, and components, chosen specifically to adhere to each model's maintenance plan, intended to maximize equipment longevity and minimize downtime in the event of a malfunction.
Warranty extension
Extended warranty up to a total of 3 years
You may also be interested in
Front-loading benchtop medical autoclaves without drying
- AHS-N-MD Series
- Classic Line
Front-loading Benchtop Medical Autoclaves with Drying
- AHS-DRY-MD Series
- Classic Line
Benchtop medical autoclaves with prevacuums and drying
- AHS-B-MD Series
- Classic Line
Subscribe to our newsletter
"*" indicates required fields